- Support units are pre-filled with grease; no additional lubrication is required before use.
- Keep the support units clean during installation and operation. Prevent dust and debris from entering the housings. Use protective measures if necessary.
- Do not disassemble the fixed-end support units, as this will compromise the preload condition.
- When inserting ball screw, carefully protect the sealing lip to avoid damage or deformation.
- For fixed-end support units, the axial locking nut should apply an appropriate amount of pressure when tightening the bearing onto the screw. For DF-type bearing arrangements, excessive tightening may reduce the preload between the bearings.
- Radial set screws on the axial locking nut must be tightened after installation is confirmed. Apply thread-locking adhesive if necessary.
- Under no circumstances should forced installation be performed.